Introduction

A rotary microtome is a microtome used for the cutting of the thin sections of the tissue samples for the microscopy, with the rotary mechanism, and it is used in the pathology, the histology, the research, and the many other applications. The rotary microtome cuts the sections by the vertical movement of the specimen block against the knife, with the rotary mechanism advancing the block, and it provides the sections with the uniform thickness; the rotary microtome consists of a specimen block holder, a knife holder, a rotary advance mechanism, a section thickness control, and the controls, and it provides features such as the adjustable section thickness; the rotary microtome is used for the sectioning of the tissue samples for the histology, for the preparation of the sections for the microscopy, for the pathology, for the research, and for many other applications, and it is an essential instrument in the histology laboratory. Rotary microtomes are used in the pathology, in the histology, in the research, in the clinical laboratories, and for many other applications. With their rotary mechanism, rotary microtomes are essential for the precise sectioning.

Rotary Microtome LRMI-T2013

Rotary Microtome LRMI-T2013



Rotary Microtome features a smooth vertical and horizontal feeding (70mm range) with a secure clamping system for stable, vibration-free cuts. It offers an adjustable slicing angle (0° ...
Rotary Microtome LRMI-T2012

Rotary Microtome LRMI-T2012



Rotary Microtome features a multi-angle specimen holder, adjustable 18° horizontally/vertically + 360° rotation for optimal positioning. It is built without complex electronics, ensuri...
Rotary Microtome LRMI-T2011

Rotary Microtome LRMI-T2011



Rotary Microtome offers a wide specimen accommodation space for samples up to 60 × 50 mm, ideal for diverse tissue types. The microtome features an adjustable thickness range (0.5–100 ...
Rotary Microtome LRMI-T2010

Rotary Microtome LRMI-T2010



Rotary Microtome is a manually operated (Paraffin embedded tissue block) cutting device with advance technology, offers slice thickness range of 0 to 60 µm. Features clipper-built case,...

Standards

ISO/TS 23824:2024-Medical laboratories-Guidance on application of ISO 15189 in anatomic pathology

Complies with the above standards, but is not limited to them.

Features

1. Rotary microtome for precise manual or semi-automatic tissue sectioning.

2. Rotary mechanism for consistent, reproducible section thickness in histology.

3. Suitable for pathology, histology, biomedical, educational and research labs.

4. Includes microtome body, blade holder, specimen holder, handwheel and manual.

5. Supports routine tissue sectioning for microscopy, histology and education.

FAQ

Q1: What testing scenarios is this microtome mainly applied to?

A: The rotary microtome is used in pathology laboratories, histology facilities, biomedical research, educational institutions, clinical diagnostics and research to perform precise sectioning of fixed, embedded tissue samples using a rotary mechanism for consistent, reproducible section thickness in routine histology and research. It supports routine histopathology sectioning for diagnosis, biomedical research tissue sectioning, educational histology teaching, clinical pathology, pharmaceutical research, and general laboratory tissue sectioning. The rotary mechanism provides smooth, controlled sectioning with the ability to produce thin, uniform sections, making it the standard instrument in histology laboratories worldwide for routine and research applications. It is essential for pathology, histology, biomedical, educational and research laboratories requiring precise rotary tissue sectioning for histopathological diagnosis, biomedical research, educational teaching, clinical diagnostics and pharmaceutical research, where the rotary mechanism provides smooth, controlled, reproducible sectioning for producing thin, uniform tissue sections for microscopic examination, supporting routine histology, diagnostic pathology and research applications requiring reliable, high-quality tissue sectioning capability.

Q2: What standards does the microtome comply with?

A: The rotary microtome follows relevant ISO, GB/T standards for histological equipment, applicable IEC 61010 safety standards (for motorized models), and relevant medical device regulations for clinical use. Blades should be certified for histological use. The instrument follows applicable safety standards for sharp blade handling. Users should verify compliance with specific facility requirements for their application, including biosafety for tissue handling.

Q3: What is the warranty period for the whole machine and key components?

A: The whole rotary microtome is covered by a 12-month warranty. The microtome body, mechanism, blade holder and specimen holder are covered, while blades, disposable blade holders and accessories are consumables. Damage from improper use, blade damage or unauthorized repair is excluded. Extended service contracts may be available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained histology or pathology personnel familiar with tissue sectioning, microtome use and biosafety. We provide operation manuals, training and application support. Proper specimen embedding, blade selection, section thickness setting, handwheel operation, section handling, blade safety and biosafety procedures are critical for quality sections and safe operation.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular maintenance required? What is the recommended maintenance cycle?

A: Mechanism lubrication and cleaning per manufacturer schedule. Blade holder and specimen holder alignment checked periodically. Section thickness verification recommended annually. Routine cleaning after each use. Full system maintenance per manufacturer schedule. Blade condition checked before each use.

Q7: Are supporting consumables universal?

A: Microtome blades (disposable or resharpenable), blade holders, embedding rings and forceps are available from histology suppliers, though compatibility should be verified. Long-term consumable cost depends on sectioning volume and blade type.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes section thickness range, blade type (disposable, resharpenable), specimen holder size, retraction mechanism, section counter, waste tray and accessories. Additional blade holders, specimen holders and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the rotary microtome and accessories with an operation manual. On-site installation and training are not included for standard manual microtomes but can be arranged for laboratory setup. Remote guidance is provided.

Q10: What types of samples are compatible with this equipment?

A: The rotary microtome sections fixed, paraffin-embedded tissue samples within the specimen size, section thickness and hardness specification. Different tissue types require specific section thickness (typically 3-5 micrometers for routine histology). Very hard or calcified tissues may require special blades or decalcification. Frozen sections require a cryostat, not a rotary microtome. Users should properly embed and trim the tissue block, select appropriate blade type and angle, set correct section thickness, use smooth, consistent handwheel operation, follow proper blade handling safety, maintain blade cleanliness, and handle sections carefully for mounting. The microtome should be placed on a stable, vibration-free surface. For clinical pathology, follow proper tissue processing and embedding protocols. The blade should be replaced when dull. The specimen should be properly oriented. The mechanism should be cleaned and lubricated regularly to maintain smooth operation. Waste paraffin and tissue should be disposed of per laboratory procedures. The rotary microtome is suitable for paraffin sections; for plastic or resin sections, a specialized microtome may be required. The handwheel should be operated with consistent, smooth motion to produce uniform sections without compression or chatter.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry