Introduction

A lab refrigerator freezer combination is a laboratory appliance that combines the refrigerator and the freezer in a single unit, used for the storage of the samples, the reagents, and the biological materials at the controlled temperatures, and it is used in the clinical, the pharmaceutical, the research, and the many other laboratories. The lab refrigerator freezer combination consists of a refrigerator compartment, which maintains the temperatures between 2 and 8 degrees Celsius, a freezer compartment, which maintains the temperatures below the freezing point, the refrigeration systems, the temperature controls, and the alarms, and it provides the controlled storage; the lab refrigerator freezer combination is used for the storage of the reagents, the media, the samples, the vaccines, the specimens, and the biological materials, for the research, for the clinical work, for the pharmaceutical storage, and for many other applications, and it is available in various sizes and configurations; the lab refrigerator freezer combination is an essential equipment for the laboratory storage. Lab refrigerator freezer combinations are used in the clinical laboratories, in the pharmaceutical industry, in the research, in the hospitals, and for many other applications. With their combined storage, lab refrigerator freezer combinations are essential for the controlled storage of the samples.

Lab Refrigerator-Freezer Combination LRFC-T2020

Lab Refrigerator-Freezer Combination LRFC-T2020



Lab Refrigerator-Freezer Combination includes dual compartments, with a total 506-liter capacity for organized storage. The multi air flow circulation offers stable temperature control. ...
Lab Refrigerator-Freezer Combination LRFC-T2019

Lab Refrigerator-Freezer Combination LRFC-T2019



Lab Refrigerator-Freezer Combination offers a 350-liter dual-zone storage capacity featuring separate refrigerator and freezer chambers. It offers automatic defrost for the refrigerator ...
Lab Refrigerator-Freezer Combination LRFC-T2018

Lab Refrigerator-Freezer Combination LRFC-T2018



Lab Refrigerator-Freezer Combination offers a total storage capacity of 350 liters for efficient sample organization. It is equipped with advanced separate refrigeration and freezing cha...
Lab Refrigerator-Freezer Combination LRFC-T2017

Lab Refrigerator-Freezer Combination LRFC-T2017



Lab Refrigerator-Freezer Combination a total capacity of 506 litres and features 2 separate chambers for refrigeration and freezing. It is equipped with advanced a microprocessor-based c...
Lab Refrigerator-T3reezer Combination LRFC-T2015

Lab Refrigerator-T3reezer Combination LRFC-T2015



Combination is a floor standing unit with freezer capacity 204 alarm sensor), human-centred design and highly efficient separate compressor and separate controller of freezer and refrige...
Lab Refrigerator-T3reezer Combination LRFC-T2016

Lab Refrigerator-T3reezer Combination LRFC-T2016



Combination unit is designed with the overall capacity of 288 and space-saving alternative for cold lab storage. Features audible and visual alarm system (built-in alarm sensor), human-c...
Lab Refrigerator-Freezer Combination LRFC-T2011

Lab Refrigerator-Freezer Combination LRFC-T2011



Lab Refrigerator-Freezer Combination is an upright cabinet with a total capacity of 528L. The refrigerator operates between 2°C to 8°C, while the freezer maintains a range from -10°C ...
Lab Refrigerator-Freezer Combination LRFC-T2014

Lab Refrigerator-Freezer Combination LRFC-T2014



Lab Refrigerator-Freezer Combination is a refrigerator-freezer combination floor type unit with user-friendly digital control panel, microprocessor controlled system with 500 set point. ...
Lab Refrigerator-Freezer Combination LRFC-T2010

Lab Refrigerator-Freezer Combination LRFC-T2010



Lab Refrigerator-Freezer Combination a total capacity of 265 operation with stable temperature control. Its ergonomic design includes a safety door lock to prevent unauthorized access. O...
Lab Refrigerator-Freezer Combination LRFC-T2013

Lab Refrigerator-Freezer Combination LRFC-T2013



Combination is a refrigerator-freezer combination floor type unit with user-friendly digital control panel, microprocessor controlled system with 310 set point. Audio-visual alarm system...
Lab Refrigerator-T3reezer Combination LRFC-T2012

Lab Refrigerator-T3reezer Combination LRFC-T2012



Combination is a floor type unit with 620 set point. Audio-visual alarm system is available for exceeding upper and lower temperature limit, open door and low voltage or electricity cut-...

Standards

IEC 61010-2-011:2019-Particular requirements for refrigerating equipment

Complies with the above standards, but is not limited to them.

Features

1. Laboratory refrigerator-freezer combination for simultaneous refrigeration and freezing storage.

2. Dual-temperature design with separate refrigerator and freezer compartments.

3. Suitable for clinical, biological, pharmaceutical, research and educational laboratories.

4. Precise temperature control with alarms for sample safety and regulatory compliance.

5. Includes refrigerator compartment, freezer compartment, controller, alarms and shelves.

FAQ

Q1: What testing scenarios is this combination mainly applied to?

A: The laboratory refrigerator-freezer combination is used in clinical laboratories, biological research, pharmaceutical storage, hospitals, educational institutions and research facilities to provide simultaneous refrigerated (2-8 degrees Celsius) and frozen (-20 degrees Celsius or below) storage for samples, reagents, media, vaccines, biological materials and chemicals in a single unit. It supports clinical laboratory sample and reagent storage, biological sample and culture preservation, pharmaceutical and vaccine storage, research reagent and enzyme storage, educational laboratory material storage, and general laboratory temperature-controlled storage. The combination unit saves space and provides convenient access to both refrigerated and frozen materials. It is essential for clinical, biological, pharmaceutical, research and educational laboratories requiring reliable dual-temperature storage for samples, reagents, vaccines, biological materials and chemicals, where proper temperature maintenance is critical for sample integrity, reagent stability, vaccine efficacy, biological material viability and regulatory compliance in healthcare, research and educational laboratory environments.

Q2: What standards does the unit comply with?

A: The laboratory refrigerator-freezer complies with relevant IEC 61010 laboratory electrical safety standards, applicable medical device standards for clinical use, and relevant GB/T standards for laboratory refrigeration. Vaccine and pharmaceutical storage follow WHO, CDC and pharmacopoeial requirements where applicable. Temperature monitoring and alarm systems should be validated for regulated storage. Calibration of temperature should be performed periodically.

Q3: What is the warranty period for the whole machine and key components?

A: The whole unit is covered by a 12-month warranty. The compressor, refrigeration system, controller and alarms are covered, while shelves, gaskets and fuses are consumables or accessories. Damage from improper use, power fluctuations or unauthorized repair is excluded. Extended warranty and service contracts are available for critical storage equipment.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation is simple: set temperatures for each compartment, allow stabilization, and store materials. No professional training is required, but users should follow proper storage practices, temperature monitoring and maintenance procedures. We provide an operation manual and remote guidance. Proper material organization, temperature monitoring and door management are important for sample safety.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular maintenance required? What is the recommended calibration cycle?

A: Temperature calibration against a reference thermometer recommended every 6-12 months for critical storage. Condenser coil cleaning periodically. Gasket and seal inspection regularly. Alarm system testing periodically. Defrosting (if manual) per schedule. Compressor and refrigeration performance checked annually. Temperature logs maintained for regulated storage.

Q7: Are supporting consumables universal?

A: Shelves, gaskets and temperature monitors are available from laboratory suppliers, though compatibility should be verified. Long-term consumable cost is low, with electricity being the main ongoing expense.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes capacity, temperature range, compartment ratio, alarm features, data logging and material grade. Additional shelves, racks and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the unit with an operation manual. On-site installation, temperature mapping and training are recommended for critical storage and can be arranged at additional cost. Remote guidance is provided.

Q10: What types of materials are compatible with this equipment?

A: The refrigerator-freezer stores samples, reagents, media, vaccines, biological materials and chemicals within the temperature ranges and capacity. Flammable or explosive materials require specially rated explosion-proof units, not standard laboratory refrigerators. Food should not be stored in laboratory units. Users should verify temperature requirements for each material, maintain proper air circulation by not overloading, monitor temperatures regularly with calibrated thermometers, respond promptly to alarms, keep doors closed as much as possible, and follow proper storage organization (refrigerator for 2-8C items, freezer for -20C items). For regulated storage (vaccines, pharmaceuticals, clinical samples), temperature mapping, continuous monitoring and alarm response procedures should be established per applicable regulations.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry