Introduction
A water content tester is an instrument used to measure the moisture or the water content of the samples, such as the solids, the powders, and the liquids, and it is used in the food, the agriculture, the chemical, the construction, and the many other industries. The water content tester measures the water content by the various methods, such as the loss on drying, in which the sample is heated and the weight loss is measured, the Karl Fischer titration, and the capacitance and the resistance methods; the water content tester consists of a heating system, a weighing system or the sensor, a processor, and the display, and it provides the water content, expressed in the percent; the water content tester is used for the measurement of the moisture of the foods and the grains, for the measurement of the moisture of the soils and the aggregates, for the measurement of the moisture of the chemicals and the pharmaceuticals, for the quality control, for the process control, and for many other applications, and it is available in various types, from the simple moisture meters to the analytical instruments; the water content tester is an essential instrument for the moisture measurement. Water content testers are used in the food industry, in the agriculture, in the chemical industry, in the construction, and for many other applications. With their moisture measurement, water content testers are essential for the moisture assessment.
Volumetric Karl Fischer Titration Tester LWT-T2024
Volumetric Karl Fischer Titration Tester is designed for accurate moisture determination in liquids, solids, and gases. It features a high-contrast touchscreen for easy operation and cle...
Coulometric Karl Fischer Titrator LWT-T2034
Coulometric Karl Fischer Titrator supports wide testing range from 1 µg H2O up to 100 mg H2O. Drift compensation is automatically controlled by for stable and accurate performance. Auto...
Volumetric Karl Fischer Titration Tester LWT-T2023
Volumetric Karl Fischer Titration Tester a measuring range from 0.001% (10ppm) to 100% with accuracy of 1.0µl. Double platinum electrode detection ensures high detection sensitivity and...
Volumetric Karl Fischer Titration Tester LWT-T2022
Volumetric Karl Fischer Titration Tester offers a titration accuracy of 1.0µl, allowing for precise reagent delivery and accurate endpoint detection. The instrument features advanced ti...
Coulometric Karl Fischer Titrator LWT-T2033
Coulometric Karl Fischer Titrator a coulometric titration measurement range of 1µg to 100mg. Detects trace amounts of moisture in liquids, soluble solids, and gases with real-time displ...
Coulometric Karl Fischer Titrator LWT-T2032
Coulometric Karl Fischer Titrator offers a measurement range of 1 µg to 200 mg with 0 to 400 mA current control. It adopts high-quality surface-mount technology components on the mother...
Volumetric Karl Fischer Titrator LWT-T2020
Volumetric Karl Fischer Titrator is an advanced tool that determines water content in a sample through a titration. It is an airproof instrument that ensures a sealed environment. Titrat...
Volumetric Karl Fischer Titrator LWT-T2021
Volumetric Karl Fischer Titrator is a cutting-edge analysis instrument. Features a dynamic online interface and stepless-speed mixing with control. Witness real-time titration curves on ...
Coulometric Karl Fischer Titrator LWT-T2031
Coulometric Karl Fischer Titrator is a benchtop unit with 5 to 40°C ambient temperature range, 3 µg to 9999.9 µg measurement range, and offers 400 mA maximum current. Excellent low-po...
Water Content Tester LWT-T2011
Water Content Tester is fabricated to determine water content in petroleum products and grease according to D95 (Test Methods for Water Content of Petroleum Products) and D7303 (Test Met...
Crude Petroleum Water Content Tester LWT-T2010
Crude Petroleum Water Content Tester designed as per D4006 Standard Test Method for Water in Crude Oil by Distillation. Widely used to determine the water content in crude oils. Features...
Water Content Tester LWT-T2010
Water Content Tester is fabricated to determine water content in petroleum products and grease according to D95 (Test Methods for Water Content of Petroleum Products) and D7303 (Test Met...
Coulometric Karl Fischer Titrator LWT-T2030
Coulometric Karl Fischer Titrator ensures accurate moisture determination across a measurement range of 0 to 100 mg. This titrator provides a high resolution of 0.1 µg for precise testi...
Standards
ISO 760-Determination of water-Karl Fischer method (general method)
ASTM E203-Standard Test Method for Water Using Volumetric Karl Fischer Titration
USP General Chapter <921>-Water Determination
Complies with the above standards, but is not limited to them.
Features
1. Water content tester for measuring moisture in solids, liquids and pastes.
2. Thermogravimetric or Karl Fischer method for accurate water determination.
3. Suitable for food, pharmaceutical, chemical, agricultural and quality control laboratories.
4. Precision heating or titration system with automatic result calculation.
5. Includes sample chamber, balance or titration unit, controller and operation manual.
FAQ
Q1: What testing scenarios is this tester mainly applied to?
A: The water content tester is used in food manufacturing, pharmaceutical quality control, chemical production, agricultural testing, cosmetics and research laboratories to measure the moisture or water content in solid, liquid and paste samples. It supports food product moisture determination for quality and shelf-life assessment, pharmaceutical water content testing per pharmacopoeial requirements, chemical raw material moisture verification, agricultural product moisture testing for storage and processing, and cosmetic formulation quality control. Water content is a critical parameter affecting product stability, texture, weight, shelf life and processing behavior. It is essential for food, pharmaceutical, chemical, agricultural and cosmetic industries requiring accurate moisture determination for product quality, regulatory compliance, process optimization, storage management and formulation control, where water content directly affects product stability, microbial growth, texture, chemical reactivity and consumer acceptance across multiple industries.
Q2: What standards does the tester comply with?
A: The water content tester supports methods referenced in ISO 1666 for starch moisture, AOAC methods for food, USP and EP for pharmaceuticals (Karl Fischer), ASTM methods, and relevant GB/T standards. The hardware complies with IEC 61010 laboratory safety standards. Calibration should use certified water standards or reference materials traceable to international standards.
Q3: What is the warranty period for the whole machine and key components?
A: The whole tester is covered by a 12-month warranty. The heating or titration system, balance, controller and sample chamber are covered, while sample pans, reagents and standards are consumables. Damage from improper sample loading or unauthorized repair is excluded. Extended service contracts are available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained analysts familiar with moisture analysis methods and sample handling. We provide operation manuals, training and application support. Proper sample preparation, method selection, calibration and result interpretation are important for accurate water content results.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration with certified water standards or reference materials recommended every 6-12 months. Balance calibration (for thermogravimetric) or burette calibration (for Karl Fischer) periodically. Daily performance verification with a control sample recommended for regulated laboratories. Reagent replacement per usage and expiration.
Q7: Are supporting consumables universal?
A: Sample pans, reagents, standards and desiccants are available from multiple qualified suppliers, though instrument-specific parts should be verified. Long-term consumable and reagent cost depends on testing volume and method type.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes measurement method (thermogravimetric or Karl Fischer), sample capacity, detection limit and software features. Additional accessories and consumable kits can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the tester and accessories with an operation manual. On-site installation, commissioning and training are not included for standard orders but can be arranged for laboratory setup projects. Remote guidance is provided.
Q10: What types of samples are compatible with this equipment?
A: The tester measures water content in solids, liquids, pastes and powders within the method range and sample capacity. Volatile samples may lose non-water volatiles during thermogravimetric testing, requiring Karl Fischer method. Highly viscous or heterogeneous samples require proper homogenization. Users should select the appropriate method based on sample type and water content, follow proper sample preparation and homogenization, use certified calibration standards, ensure representative sampling, and report results with method specification for accurate, reproducible water content determination.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.













