Introduction
A semi automatic microtome is a microtome with the semi-automated operation, used for the sectioning of the biological specimens embedded in the paraffin or the resins, and it is used in the histology, the pathology, the research, and the many other laboratories. The semi automatic microtome consists of a specimen holder, a knife holder with the blade, a mechanism for the advancement of the specimen, a wheel or a lever for the manual cutting, and the automated features, such as the motorized advancement and the retraction, and it cuts the thin sections of the specimen with the manual or the semi-automated operation, with the section thickness adjusted; the semi automatic microtome is used for the sectioning of the tissue specimens for the microscopy, for the preparation of the slides for the histology and the pathology, for the sectioning of the embedded specimens, for the research, and for many other applications, and it is available in various models, with the different section thickness ranges; the semi automatic microtome provides an efficient and a precise sectioning, with features such as the adjustable speed and the trimming, and it is an essential instrument in the histology laboratory. Semi automatic microtomes are used in the histology laboratories, in the pathology departments, in the research institutions, in the hospitals, and for many other applications. With their semi-automated operation, semi automatic microtomes are essential for the tissue sectioning.
Semi-S2utomatic Microtome T-S2MC-S2100
Semi-S2utomatic Microtome T-S2MC-S2101
Standards
ISO/TS 23824:2024-Medical laboratories-Guidance on application of ISO 15189 in anatomic pathology
Complies with the above standards, but is not limited to them.
Features
1. Semi-automatic microtome for precise sectioning of biological and material specimens.
2. Motorized feed with manual sectioning stroke combines reproducibility with control.
3. Digital thickness setting from 0.5 to 60 micrometers for routine and research use.
4. Suitable for histopathology, clinical diagnostics and biological research laboratories.
5. Includes blade holder, specimen clamp, waste tray and operation manual.
FAQ
Q1: What testing scenarios is this microtome mainly applied to?
A: The semi-automatic microtome is used in histopathology laboratories, clinical diagnostic departments, biological research institutions and veterinary pathology to cut thin, uniform sections of paraffin-embedded tissue for microscopic examination. It supports routine histology slide preparation, immunohistochemistry sample processing, clinical diagnosis, research tissue sectioning and teaching. The semi-automatic design provides motorized feed for consistent thickness while retaining manual control over the sectioning stroke, reducing operator fatigue and improving section quality compared with fully manual microtomes. It is essential for pathology laboratories and research facilities requiring reliable, reproducible tissue sections for accurate diagnosis, biomarker analysis and histological evaluation of tissue samples from clinical trials, animal studies and patient specimens.
Q2: What standards does the microtome comply with?
A: The microtome is designed with reference to relevant ISO and GB/T standards for medical laboratory equipment and histopathology instrumentation. Clinical diagnostic applications follow validated laboratory procedures and applicable quality management standards including ISO 15189 where accredited. Section thickness accuracy should be verified for critical applications.
Q3: What is the warranty period for the whole machine and key components?
A: The whole microtome is covered by a 12-month warranty. The motor, feed mechanism and control panel are covered, while blades, blade holders and waste trays are consumables or accessories. Damage from improper blade installation, dropping or unauthorized repair is excluded.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained histology technicians familiar with tissue processing and microtomy technique. We provide an operation manual and remote guidance. Proper specimen orientation, blade selection, sectioning technique and blade safety are important for quality sections and operator safety.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular maintenance required? What is the recommended maintenance cycle?
A: Section thickness accuracy can be verified periodically with a calibrated reference. Blade holder alignment and feed mechanism lubrication follow the manufacturer schedule. Routine cleaning and blade replacement are part of daily operation. Full preventive maintenance is recommended annually for high-use instruments.
Q7: Are supporting consumables universal?
A: Microtome blades are available from multiple suppliers in standard dimensions. Blade holders may be model-specific. Long-term consumable cost is moderate, with blades being the main recurring item.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes thickness range, blade holder type, specimen clamp and accessory packages. Additional blades, blade holders and anti-roll plates can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the microtome, blade holder and accessories with an operation manual. Remote setup guidance is provided. On-site installation and training are not included for standard orders but can be arranged for laboratory setup projects.
Q10: What types of samples are compatible with this equipment?
A: The microtome sections paraffin-embedded tissue samples and other compatible embedded materials within the thickness range. Frozen sections require a cryostat rather than a room-temperature microtome. Hard or calcified samples may require decalcification. Users should follow proper blade safety procedures, ensure specimens are properly oriented and clamped, use appropriate blade angle and clearance, and dispose of blades safely in designated sharps containers to prevent injury.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.