Introduction

Freezing Point Apparatus delivers results with temperature range of -40°C (degrees Celsius) to 0°C (degrees Celsius). They ensure consistent testing by offering stable cooling system and advanced digital display for clear readings. Their construction is designed for efficient operation and long-term durability with minimal maintenance. They come with safety features that prevent overheating and protect samples during testing. Freezing Point Apparatus are suitable for determining freezing points of solutions in laboratories and industrial settings.

Automatic Freezing Point Tester T-FZP-S2100

Automatic Freezing Point Tester T-FZP-S2100

Automatic Freezing Point Tester offers freezing point measuring range of -54°C to 2°C with a temperature controlling accuracy of ±0.1℃. This floor standing unit incorporates an importe...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Precise temperature ramp and detection give repeatable points.

2. Calibration with reference standards supports accuracy.

3. Adjustable ramp rates follow different standard methods.

4. Automatic detection reduces operator judgement.

5. Clear display or magnified view shows the melting transition.

FAQ

What are the main applications of the Freezing Point Apparatus?

The Freezing Point Apparatus is used to determine the melting, softening or dropping point of substances, supporting identity and purity checks. It is used in chemical, pharmaceutical, polymer, food and quality-control laboratories.

What standards does the Freezing Point Apparatus comply with?

The instrument is designed with reference to applicable pharmacopoeia, ISO, ASTM and GB/T methods for melting or softening point and IEC 61010 electrical safety. Procedures must follow the relevant method. Compliance documentation can be provided on request.

What does the warranty cover?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

How easy is the Freezing Point Apparatus to use?

No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Freezing Point Apparatus be calibrated?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Are the consumables universal or proprietary?

The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.

Can it be adapted to our requirements?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.

What maintenance and safety points matter?

Do not use contaminated or overfilled capillaries, heat too quickly or skip temperature calibration. Prepare samples consistently. Follow the operating instructions.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry