Introduction
Freezer reach temperatures as low as -86°C (degrees Celsius) providing reliable storage for sensitive specimens. They offer advanced insulation and sturdy door seals ensuring maintained temperatures for sample integrity. Their digital control panels allow easy adjustments while alarm systems signal any temperature deviations. They are designed with ample storage compartments and shelving for organized specimen management. Laboratory Freezer are suitable for preserving biological samples and reagents in research and clinical settings.
-86℃ Ultra Low Temperature Freezer T-ULT-C108
-86℃ Ultra Low Temperature Freezer T-ULT-C107
-86℃ Ultra Low Temperature Freezer T-ULT-C106
-30℃ Low Temperature Freezer T-LT-506
-30°C Low Temperature Freezer T-LT-505
-86℃ Ultra Low Temperature Freezer T-ULT-C105
-30°C Low Temperature Freezer T-LT-504
-30°C Low Temperature Freezer T-LT-502
-30°C Low Temperature Freezer T-LT-501
-86℃ Ultra Low Temperature Freezer T-ULT-C111
-86℃ Ultra Low Temperature Freezer T-ULT-D105
-86℃ Ultra Low Temperature Freezer T-ULT-D106
-86℃ Ultra Low Temperature Freezer T-ULT-D104
-86℃ Ultra Low Temperature Freezer T-ULT-D103
-86℃ Ultra Low Temperature Freezer T-ULT-E103
-L60℃ Low Temperature Freezer T-LTF-S2104
-40℃ Low Temperature Freezer T-LF-L2102
-40℃ Low Temperature Freezer T-LF-L2101
-40℃ Low Temperature Freezer T-LF-L2100
-25℃ Biomedical Freezer T-L2F-S2101
-25℃ Biomedical Freezer T-L2F-S2100
-150℃ Cryogenic Freezer T-CF-S2100
-86℃ Ultra Low Temperature Freezer T-ULT-D101
-86℃ Ultra Low Temperature Freezer T-ULT-D100
-86℃ Ultra Low Temperature Freezer T-ULT-L2102
-86℃ Ultra Low Temperature Freezer T-ULT-L2101
-86℃ Ultra Low Temperature Freezer T-ULT-E101
-86℃ Ultra Low Temperature Freezer T-ULT-E100
-86°C Water Cooled ULT Freezer T-WF-S502
-86°C Water Cooled ULT Freezer T-WF-S501
-L60℃ Low Temperature Freezer T-LTF-S2101
-L60℃ Low Temperature Freezer T-LTF-S2102
-L60℃ Low Temperature Freezer T-LTF-S2100
-40℃ Low Temperature Freezer T-LF-S2103
-40℃ Low Temperature Freezer T-LF-S2102
-40℃ Low Temperature Freezer T-LF-S2101
-40℃ Low Temperature Freezer T-LF-S2100
-40℃ Low Temperature Freezer T-LF-S2104
Standards
IEC 61010-2-011:2019-Particular requirements for refrigerating equipment
IEC 62552-1:2015-Household refrigerating appliances-Characteristics and test methods-Part 1: General requirements
ISO 20387:2018-Biotechnology-Biobanking-General requirements for biobanking
ISO/TS 20388:2021-Biotechnology-Biobanking-Requirements for animal biological material
Complies with the above standards, but is not limited to them.
Features
1. Lockable door with a silicone gasket secures contents and seals in cold.
2. High-density foam insulation minimises cold loss and energy use.
3. Audible and visual alarms warn of temperature excursions or power failure.
4. Offered in 220V or 110V versions to suit the local power supply.
5. Robust compressor and refrigeration circuit deliver consistent performance.
FAQ
What is the Freezer mainly used for?
The Freezer is used for medium- to long-term storage of samples, reagents, biological materials and specimens at sub-zero temperatures. It serves clinical, diagnostic, research and industrial laboratories that need stable freezing without reaching ultra-low temperature levels.
Which standards and regulations apply to the Freezer?
The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for laboratory freezers. Storage of biological materials should follow applicable laboratory and biobanking guidance. Compliance documentation can be provided on request.
What does the warranty cover?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
Will staff need special training?
The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Is calibration included?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Are consumables and spare parts easy to obtain?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can the Freezer be customised?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
How is the Freezer commissioned?
Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.
What maintenance and safety points matter?
Flammable materials, pressurised containers and samples needing ultra-low temperatures should not be stored in this unit. Use low-temperature-rated containers, avoid overloading and keep vents clear. Follow laboratory safety regulations.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.