Introduction

Biological Safety Cabinet Class II Type A2 offers protection with airflow speeds of 0.5 meters per second. They provide contamination-free environments through HEPA filters and negative air pressure. Their double-wall design ensures air containment while their UV light enables decontamination between procedures. They have adjustable work surfaces and ergonomic designs for user comfort. Biological Safety Cabinet Class II Type A2 cabinets are suitable for laboratories handling microbiological research, hazardous agents, and other sensitive biological samples.

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2212

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2212

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2213

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2213

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2205

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2205

Biological Safety Cabinet Class Ⅱ Type A2 operates with a maximum opening width of 480 mm and a testing safety height of 200 mm, facilitating easy access. Integrates HEPA filters, which o...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2210

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2210

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2211

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2211

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2207

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2207

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2208

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2208

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2209

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2209

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2206

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2206

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2204

Biological Safety Cabinet Class Ⅱ Type A2 T-L2C-S2204

Biological Safety Cabinet Class Ⅱ Type A2 is designed with an enclosed workspace with a ventilated hood to protect users from exposure to pathogenic microorganisms. Configured with HEPA f...
Biological Safety Cabinet Class II T-L2SC-S2104

Biological Safety Cabinet Class II T-L2SC-S2104

Biological Safety Cabinet Class II supports two-operator workflow. Its visual front window features 10° tilt angle, ensuring ergonomic comfort during operation. Its split-style structure ...
Biological Safety Cabinet Class II T-L2SC-S2102

Biological Safety Cabinet Class II T-L2SC-S2102

Biological Safety Cabinet Class II offers 0.55 m/s inflow velocity. Its high-efficiency HEPA filter offer delivers 99.995% particle removal. It features automatic UV sterilization with sch...
Biological Safety Cabinet Class II T-L2SC-S2103

Biological Safety Cabinet Class II T-L2SC-S2103

Biological Safety Cabinet Class II offers inflow air velocity of 0.55 m/s. Its split-style structure features removable rack with wheels and adjustable screw rods for stability. Its air cl...
Biological Safety Cabinet Class II T-L2SC-S2100

Biological Safety Cabinet Class II T-L2SC-S2100

Biological Safety Cabinet Class II offers inflow velocity of 0.55 m/s. It features automatic UV sterilization scheduling and timing functions for contamination-free environment. Its high-e...
Biological Safety Cabinet Class II T-L2SC-S2101

Biological Safety Cabinet Class II T-L2SC-S2101

Biological Safety Cabinet Class II supports two-operator workflow. It features intelligent control system with LCD, displaying air velocity, filter life, and alerts. Its stainless-steel wo...

Standards

NSF/ANSI 49-Biosafety Cabinetry: Design, Construction, Performance, and Field Certification

EN 12469-Biotechnology-Performance criteria for microbiological safety cabinets

Complies with the above standards, but is not limited to them.

Features

1. Smooth stainless or steel surfaces are easy to clean.

2. Clear work zone with good visibility and integrated lighting.

3. Low face-velocity variation maintains a stable protective zone.

4. Vertical or horizontal airflow suits protection of samples or products.

5. Low-noise fan supports comfortable working conditions.

FAQ

What are the main applications of the Biological Safety Cabinet Class II Type A2?

The Biological Safety Cabinet Class II Type A2 is used to provide clean or controlled airflow for handling samples, powders or operations that need protection from contamination or airborne exposure. It supports pharmaceutical, microbiological, analytical and electronics work.

Which standards and regulations apply to the Biological Safety Cabinet Class II Type A2?

The unit is designed with reference to IEC 61010 electrical safety, applicable clean-air and containment standards and relevant GB/T methods. Filters and airflow should be tested periodically. Compliance documentation can be provided on request.

How long is the warranty period?

A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.

Will staff need special training?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Biological Safety Cabinet Class II Type A2 be calibrated?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Are the consumables universal or proprietary?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the Biological Safety Cabinet Class II Type A2 be customised?

The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Biological Safety Cabinet Class II Type A2?

Do not handle highly toxic or pathogenic agents beyond the containment class, block the face opening or rely on expired filters. Verify airflow and filter integrity. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.