Introduction

A water portable turbidity meter is a portable instrument used to measure the turbidity of the water in the field, and it is used in the environmental monitoring, the water treatment, the field, and the many other applications. The water portable turbidity meter measures the turbidity by the nephelometric method, in which the light scattered by the particles in the sample is measured at a specified angle, and it provides the turbidity value, expressed in nephelometric turbidity units (NTU), with features such as the calibration and the data logging; the water portable turbidity meter consists of a portable meter with the display, a light source, a sample cell or the cuvette, a detector, and the battery, and it is designed for the field use, with a compact and a rugged construction, and it is used for the measurement of the turbidity of the rivers, the lakes, the groundwater, the wastewater, and the drinking water, for the field monitoring, for the quality control, and for many other applications; the water portable turbidity meter is an essential instrument for the field water analysis. Water portable turbidity meters are used in the environmental monitoring, in the water treatment, in the field, in the laboratories, and for many other applications. With their portability, water portable turbidity meters are essential for the on-site turbidity measurement.

Portable Turbidity Meter T-S221PTM

Portable Turbidity Meter T-S221PTM


Portable Turbidity Meter provides dual-range measurement of 0 to 20 NTU and 0 to 1000 NTU, ensuring accurate turbidity analysis. It operates within a temperature range of 5 to 40 °C for ...
Portable Turbidity Meter T-S220PTM

Portable Turbidity Meter T-S220PTM


Portable Turbidity Meter measures turbidity from 0 to 1000 NTU and suspended solids from 0 to 1000 mg/L using 90° scattered and 180° transmitted light. It uses near-infrared technology ...
Portable Turbidity Meter T-S218PTM

Portable Turbidity Meter T-S218PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S216PTM

Portable Turbidity Meter T-S216PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S217PTM

Portable Turbidity Meter T-S217PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S214PTM

Portable Turbidity Meter T-S214PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S215PTM

Portable Turbidity Meter T-S215PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S212PTM

Portable Turbidity Meter T-S212PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S213PTM

Portable Turbidity Meter T-S213PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S219PTM

Portable Turbidity Meter T-S219PTM


Portable Turbidity Meter measures turbidity from 0 to 1100 NTU, 0 to 275 EBC, and 0 to 9999 ASBC using a 30 ml sample. It uses the nephelometric method with an infrared diode and silicon ...
Portable Turbidity Meter T-S210PTM

Portable Turbidity Meter T-S210PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...
Portable Turbidity Meter T-S211PTM

Portable Turbidity Meter T-S211PTM


Portable turbidity meter is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. A...

Standards

ISO 7027-1:2016-Water quality-Determination of turbidity-Quantitative methods

EPA Method 180.1-Determination of Turbidity by Nephelometry

Complies with the above standards, but is not limited to them.

Features

1. Portable turbidity meter for field measurement of suspended particle concentration in water.

2. Nephelometric detection with waterproof design for outdoor and field use.

3. Suitable for environmental monitoring, water treatment, aquaculture and field survey.

4. Digital display with calibration functions, data logging and backlight for low-light use.

5. Includes sample vials, calibration standards, carrying case and operation manual.

FAQ

Q1: What testing scenarios is this instrument mainly applied to?

A: The portable turbidity meter is used in environmental field monitoring, water treatment plant inspection, aquaculture management, industrial water testing and emergency response to measure turbidity on-site. It supports river and lake water quality assessment, drinking water source monitoring, wastewater discharge inspection, filtration process verification, aquaculture pond management and environmental compliance field testing. The portable design allows immediate measurement at sampling locations, eliminating sample transport and preservation issues that can affect particle settling and turbidity readings. It is essential for field environmental scientists, water treatment operators, aquaculture managers and regulatory inspectors requiring real-time turbidity data in remote or outdoor locations.

Q2: What standards does the instrument comply with?

A: The meter complies with ISO 7027 for water quality turbidity determination, EPA Method 180.1, relevant GB/T 13200 and HJ standards, and IEC 60529 for ingress protection. Calibration should use certified formazin or AMCO-AEPA standards traceable to international standards.

Q3: What is the warranty period for the whole machine and key components?

A: The whole meter is covered by a 12-month warranty. The optical system, detector and controller are covered, while sample vials and calibration standards are consumables excluded from warranty. Optical window damage from scratches or improper cleaning is also excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires basic training in calibration and field measurement. We provide an operation manual and remote guidance. Proper vial handling, sample preparation and calibration procedures are important for accurate field results. The waterproof design simplifies outdoor operation.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Calibration with certified turbidity standards should be performed before each field use session. Full meter calibration is recommended every 6-12 months. Sample vials should be inspected and replaced when scratched. Optical window cleaning should follow the manufacturer schedule.

Q7: Are supporting consumables universal?

A: Calibration standards and sample vials are available from multiple suppliers, though certified standards and matched vials are recommended. Long-term consumable cost is low to moderate.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes measurement range, optical configuration, data logging and carrying case. Additional vials, standards and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: No installation is required. The package includes the meter, vials, standards, carrying case and instruction manual. On-site training service is available at additional cost for field teams.

Q10: What types of samples are compatible with this equipment?

A: The meter measures turbidity of water and clear liquids within the measurement range. Highly colored samples may interfere with nephelometric measurement. Very high turbidity samples may require dilution. Users should handle sample vials carefully to avoid scratches and bubbles, allow samples to degas before measurement, and follow proper calibration and sample preparation procedures. The instrument should be protected from extreme temperatures, impacts and water immersion beyond the rated ingress protection.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry