Introduction
A water benchtop turbidity meter is a benchtop instrument used to measure the turbidity of the water and the liquids, which indicates the cloudiness caused by the suspended particles, and it is used in the water treatment, the environmental monitoring, the laboratories, and the many other applications. The water benchtop turbidity meter measures the turbidity by the nephelometric method, in which the light scattered by the particles in the sample is measured at a specified angle, typically 90 degrees, and it provides the turbidity value, expressed in nephelometric turbidity units (NTU), with features such as the calibration and the data logging; the water benchtop turbidity meter consists of a benchtop meter, a light source, a sample cell, a detector, and the controls, and it is used for the measurement of the turbidity of the drinking water, the wastewater, the process water, and the environmental samples, for the quality control, for the monitoring, for the compliance with the standards, and for many other applications, and it is an essential instrument for the water analysis. Water benchtop turbidity meters are used in the water treatment, in the environmental monitoring, in the laboratories, in the industry, and for many other applications. With their turbidity measurement, water benchtop turbidity meters are essential for the water quality assessment.
Benchtop Turbidity Meter T-S216BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S215BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S212BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S213BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S214BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S210BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S211BTM
Benchtop turbidity meter is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prol...
Benchtop Turbidity Meter T-S217BTM
Benchtop Turbidity Meter is a benchtop type microprocessor controlled unit for precision turbidity measurement, employs Nephelometric principle with 90° detection. Offers ≤±6% accuracy...
Standards
ISO 7027-1:2016-Water quality-Determination of turbidity-Quantitative methods
Complies with the above standards, but is not limited to them.
Features
1. Benchtop turbidity meter for measuring suspended particle concentration in water.
2. Nephelometric detection with 90-degree scattered light measurement for accurate turbidity.
3. Suitable for drinking water, wastewater, environmental and industrial water quality testing.
4. Digital display with calibration functions, range selection and data output.
5. Includes sample vials, calibration standards and operation manual for immediate use.
FAQ
Q1: What testing scenarios is this instrument mainly applied to?
A: The benchtop turbidity meter is used in water treatment plants, environmental monitoring laboratories, beverage manufacturing, pharmaceutical production and research institutions to measure turbidity caused by suspended particles in water and other liquids. It supports drinking water quality compliance, wastewater effluent monitoring, filtration process control, beverage clarity assessment and environmental water quality assessment. Turbidity measurement indicates the clarity of water and the presence of suspended solids such as clay, silt, organic matter and microorganisms, which is a critical parameter for drinking water safety, filtration efficiency and aesthetic quality. The benchtop design provides higher accuracy and lower detection limits than portable meters for laboratory-based regulatory compliance testing.
Q2: What standards does the instrument comply with?
A: The meter complies with ISO 7027 for water quality turbidity determination, EPA Method 180.1, ASTM D7315 and relevant GB/T 13200 and HJ standards. The instrument complies with IEC 61010 laboratory safety standards. Calibration should use certified formazin or AMCO-AEPA standards traceable to international standards.
Q3: What is the warranty period for the whole machine and key components?
A: The whole meter is covered by a 12-month warranty. The optical system, detector and controller are covered, while sample vials and calibration standards are consumables excluded from warranty. Optical window damage from scratches or improper cleaning is also excluded.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is simple: fill the vial, place in the chamber and read the display. No professional training is required, but users should follow calibration procedures, vial handling instructions and sample preparation guidelines to avoid errors from bubbles, scratches or contamination. We provide an operation manual and remote guidance.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Calibration with certified turbidity standards should be performed before each use session or at least daily for critical measurements. Full meter calibration is recommended every 6-12 months. Sample vials should be inspected and replaced when scratched. Optical window cleaning should follow the manufacturer schedule.
Q7: Are supporting consumables universal?
A: Calibration standards and sample vials are available from multiple suppliers, though certified standards and matched vials are recommended for accuracy. Long-term consumable cost is low, with vial replacement being the main recurring item.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes measurement range, optical configuration and data output. Additional vials, standards and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: No installation is required beyond power connection. The package includes the meter, vials, standards and instruction manual. On-site calibration service is available at additional cost.
Q10: What types of samples are compatible with this equipment?
A: The meter measures turbidity of water and clear liquids within the measurement range. Highly colored samples may absorb light and interfere with nephelometric measurement, requiring ratio-compensating instruments. Very high turbidity samples may require dilution. Users should handle sample vials carefully to avoid scratches and bubbles, allow samples to degas before measurement, and follow proper calibration and sample preparation procedures for accurate results.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.