Introduction
Oil Particle Counters provide accurate contamination monitoring in oils and hydraulic systems across various industries. Their semiconductor laser technology identifies and analyzes suspended particles across a broad size range. Their multi-channel detection offers real-time data, ideal for on-site testing and mobile diagnostics. They feature a digital display for convenient control and monitoring. oil particle counters are perfect for use in automotive industries, aerospace facilities, oil refineries, manufacturing plants, and laboratories.
Oil Particle Counter T-OPC-S2101
Oil Particle Counter T-OPC-S2100
Portable Oil Particle Counter T-S212POC
Portable Oil Particle Counter accurately detects particle sizes ranging from 0.8μm to 600μm, ensuring precise oil contamination analysis. It utilizes a high-precision semiconductor lase...
Portable Oil Particle Counter T-S211POC
Portable Oil Particle Counter detects particles ranging from 1 to 500 μm in size for precise analysis of fluid contamination. It utilizes the photoresist (shading) counting method as per...
Portable Oil Particle Counter T-S210POC
Portable Oil Particle Counter detects oil contamination level as per ISO11171-1999 standard. Features photoresist measuring principle with high precision laser sensor and metering pump sa...
Oil Particle Counter T-S211OPC
Oil Particle Counter used light blockage measuring principle to determine solid particles in oil. Features semi-conductor laser as light source to provide 4 or 1 µm of sensitivity.
Desig...
Oil Particle Counter T-S210OPC
Oil Particle Counter is a high-precision unit having high-pressure syringe pump and sensors. Adopts counting principle of photoresist (shading) method, has semiconductor laser as light so...
Standards
ISO 13320:2020-Particle size analysis-Laser diffraction methods
Complies with the above standards, but is not limited to them.
Features
1. Configurable channels and alarms match monitoring requirements.
2. Controlled pump or flow keeps sampling consistent.
3. Data logging and export support cleanroom and oil reports.
4. Rechargeable battery and low-power design support field use.
5. Precise optical sensor counts and sizes particles by channels.
FAQ
What is the Oil Particle Counter mainly used for?
The Oil Particle Counter is used to count particles or determine particle size and distribution in air, liquids or samples. It supports cleanroom monitoring, filter testing, hydraulic-oil checks, environmental work and quality control.
Which standards and regulations apply to the Oil Particle Counter?
The instrument is designed with reference to applicable ISO and GB/T standards for particle counting and cleanroom monitoring and IEC 61010 electrical safety. Procedures should follow the relevant standard. Compliance documentation can be provided on request.
What warranty comes with the Oil Particle Counter?
We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.
Is the Oil Particle Counter difficult to operate?
Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Oil Particle Counter be calibrated?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Are the consumables universal or proprietary?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Can it be adapted to our requirements?
Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.
Is installation and commissioning included?
The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.
What should be avoided when using the Oil Particle Counter?
Do not sample condensing or contaminated atmospheres, use a blocked inlet or skip flow checks. Keep the sensor clean and calibrated. Follow the operating instructions.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.