Introduction
Table-top autoclaves are compact and reliable sterilization devices suitable for smaller medical and dental practices, beauty salons, and laboratories. Designed to meet standards, they are capable of sterilizing solid instruments efficiently. autoclaves operate with a heating element to reach sterilization temperatures and maintain pressure through gravity displacement, making them suitable for basic sterilization needs. They offer simplicity and user-friendliness with easy-to-use interfaces and pre-set programs, ensuring hassle-free operation. While autoclaves are more affordable than their advanced counterparts, they still prioritize safety, featuring safety locks, pressure release valves, and alarms to protect users from potential hazards. table-top autoclaves are a cost-effective solution for basic sterilization, offering peace of mind and hygiene in various settings where compact and reliable sterilization is essential.
Table Top Autoclave T-S214TNA
Class N Table top autoclave is a unit with microcomputer control system for arbitrary process of sterilization. The built-in steam generator provides rapid cycles of saturated steam. It i...
Table Top Autoclave T-S213TNA
Class N Table top autoclave is a unit with microcomputer control system for arbitrary process of sterilization. The built-in steam generator provides rapid cycles of saturated steam. It i...
Table Top Autoclave T-S212TNA
Class N Table top autoclave is a unit with microcomputer control system for arbitrary process of sterilization. The built-in steam generator provides rapid cycles of saturated steam. It i...
Table Top Autoclave T-S210TNA
Class N Table top autoclave is a unit with microcomputer control system for arbitrary process of sterilization. The built-in steam generator provides rapid cycles of saturated steam. It i...
Table Top Autoclave T-S211TNA
Class N Table top autoclave is a unit with microcomputer control system for arbitrary process of sterilization. The built-in steam generator provides rapid cycles of saturated steam. It i...
Table Top Autoclave T-S213TBA
Class B Table top autoclave is a microcomputer control system with three times better pre-vacuum drying function. The built-in steam generator provides rapid cycles of saturated steam. It...
Table Top Autoclave T-S214TBA
Class B Table top autoclave is a microcomputer control system with three times better pre-vacuum drying function. The built-in steam generator provides rapid cycles of saturated steam. It...
Table Top Autoclave T-S210TBA
Class B Table top autoclave is a microcomputer control system with three times better pre-vacuum drying function. The built-in steam generator provides rapid cycles of saturated steam. It...
Table Top Autoclave T-S212TBA
Class B Table top autoclave is a microcomputer control system with three times better pre-vacuum drying function. The built-in steam generator provides rapid cycles of saturated steam. It...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Vertical, horizontal and benchtop models suit various spaces.
2. Printer or data-logger option provides cycle records.
3. Digital display shows temperature, pressure and cycle stage.
4. Quiet operation and heat-insulated panels suit busy work areas.
5. Fast cycles and effective drying improve instrument turnaround.
FAQ
What is the Table Top Autoclave mainly used for?
The Table Top Autoclave is used to sterilise instruments, glassware, media and waste using pressurised saturated steam. It is essential in microbiology, clinical, dental, pharmaceutical and research laboratories and in central sterile supply.
What standards does the Table Top Autoclave comply with?
The unit is designed with reference to applicable pressure-vessel safety rules, IEC 61010 electrical requirements and relevant GB/T standards for sterilizers. Sterilization cycles should follow applicable standards and validated procedures. Compliance documentation can be provided on request.
How long is the warranty period?
The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.
Is the Table Top Autoclave difficult to operate?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Table Top Autoclave need calibration or verification?
To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.
Are the consumables universal or proprietary?
The instrument uses standard, widely available consumables rather than special locked items. Replacement parts, accessories and consumables can be ordered from us against the model number. We keep common service parts in stock for prompt supply.
Can the Table Top Autoclave be customised?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Do you provide on-site installation?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What should be avoided when using the Table Top Autoclave?
Do not sterilise sealed containers or incompatible materials, and never open the chamber while pressurised. Ensure air removal and drying for effective sterilization. Follow pressure-vessel safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.