Introduction
Laboratory water-cooled chillers are highly efficient refrigeration systems designed to remove heat from a building or industrial process by using water as a heat exchange medium. These systems circulate water through a condenser, compressor, and evaporator to extract heat and cool the air or process, making them ideal for large-scale applications. Unlike air-cooled chillers, they require cooling towers and a constant water source to dissipate heat effectively, which can be more complex and expensive to install and maintain. laboratory water-cooled chillers are valued for their superior efficiency and cooling capacity, making them suitable for cooling data centers, industrial processes, and large commercial facilities. Their ability to maintain consistent cooling performance in high-heat environments and their reduced noise output compared to air-cooled counterparts make them a popular choice in scenarios where precise temperature control and minimal environmental impact are critical.
Water cooled chiller T-S292WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S293WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S288WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S289WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S290WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S291WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S287WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S286WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S282WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S283WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S284WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S285WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S280WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Water cooled chiller T-S281WCC
Water cooled chiller is a micro-computer controlled chillers with a temperature range from 3 °C to 30 °C. It is equipped with a refrigerant type of R134A/R22/R407C/R410A/R404A. It has...
Standards
AHRI 550/590 (I-P)-2023-Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle
GB/T 18430.1-Water-chilling (heat pump) packages using the vapor compression cycle for industrial and commercial applications
EN 14511-Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors
Complies with the above standards, but is not limited to them.
Features
1. Compressor or thermoelectric cooling suits different loads.
2. Easy drain and fill support maintenance.
3. Various capacities cover small instruments to larger processes.
4. Open or closed loop configurations fit applications.
5. Over-temperature, low-level and pressure protection included.
FAQ
What is the Water cooled chiller mainly used for?
The Water cooled chiller is used to cool processes, instruments, reactors or samples to controlled temperatures by recirculating fluid. It supports laboratories, lasers, reactors, industrial equipment and thermal control.
Which standards and regulations apply to the Water cooled chiller?
The chiller is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for recirculating cooling equipment. Cooling capacity should match the heat load. Compliance documentation can be provided on request.
What does the warranty cover?
A 12-month warranty applies to the complete equipment against defects in materials and workmanship. It excludes consumables, wearing components and accidental or misuse damage. Our service team handles claims against the serial number, and longer cover can be arranged.
Is the Water cooled chiller difficult to operate?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
What is the typical lead time for order delivery?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Water cooled chiller need calibration or verification?
Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.
Are the consumables universal or proprietary?
Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.
Can the Water cooled chiller be customised?
The standard model can be configured with selected accessories and operating options to suit the task. Non-standard requests are assessed before quotation so the final build is clearly defined. We confirm details before production.
Is installation and commissioning included?
Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.
What should be avoided when using the Water cooled chiller?
Do not run without fluid, block airflow or use unsuitable coolant. Maintain fluid quality and keep filters and vents clean. Follow the operating instructions.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.